About This Product

Dynamic Heat Control from Napoleon

Dynamic Heat Control is a system for managing the heat produced by the appliance at and around the fireplace. The purpose of Dynamic Heat control is to move the heat away from the fireplace to allow it to circulate more effectively within the living space. 

Benefits of Dynamic Heat Control

  • Greatly reduces clearances directly above fireplace allowing for TV and or artwork*
  • Heat is circulated more consistently through the living space increasing comfort in front of the fireplace
  • Increase "real world" efficiency as heat is mored into the room rather than retained inside the enclosure
  • Complete flexibility in selection of finishing materials**

*Always check appliance manufacturers’ recommendations to confirm suitability and any special environmental limitations. For valuable or antique items, always refer to expert preservation instructions as some items require specifically controlled temperature and/or humidity.

**In most common installation configurations, some specific installations require special provisions. See minimum clearances to combustible enclosures section of manual linked below for more details. Ensure to strictly adhere to instructions. 

Compatible Fireplaces:

  • Vector Series
  • Luxuria Series (DHC Included with Fireplace)
  • Tall Vector Series 
  • Elevation X Series

Installation Options

Choose from 1 of 4 installation options (see manual below for me details) 

1. OPEN ENCLOSURE (enclosure stops short of the ceiling) 

Leaves a complete air outlet opening above the enclosure to provide the necessary air circulation path for the Dynamic Heat Control™ system. This has been found to be well accepted with respect to final appearance and offer minimal distraction. It also allows for efficient circulation of air within the room.

This option offers the simplest method for framing and installation. Limit the air outlet opening height to 4” to reduce the risk of items inadvertently falling into the enclosure. The air outlet opening must extend around the entire perimeter, or the entire front face of the enclosure, where the enclosure runs from wall to wall.

2. FRONT OPENING

Requires an air outlet opening to be framed no more than 1.5” below the enclosure top to avoid trapping heat in the upper areas and the air outlet opening centered on the appliance center.

Minimum air outlet opening dimensions must be followed. Framing the air outlet opening lower will overheat the appliance, the enclosure, and finishing material.

3. REAR OPENING

Requires air outlet opening to be framed no more than 1.5" below the enclosure top to avoid trapping heat in the upper areas and centered on the appliance center. 

Minimum air outlet opening dimensions must be followed. The opening is required. Framing the rear opening lower will overheat the appliance, the enclosure, and finished material. 

4. OPEN ENCLOSURE w/HARD COMBUSTIBLE VALENCE

Similar to installation option 1 with the addition of a hard combustible valence. 

Minimum opening dimensions and valence dimensions must be followed. Restricting air movement within the valence area will overheat the appliance, the enclosure and finishing material. 

    Shipping & Returns

    Free curbside freight delivery on every order over $399. Inspect the shipment before signing and note any damage on the delivery receipt — freight damage claims must be reported within 5 business days. Most items can be returned within 30 days of delivery as long as the product hasn't been installed, is in the same condition you received it, and all original packaging is intact. Return shipping and the original outbound freight cost are deducted from the refund, and a manufacturer restocking fee may apply. Custom and made-to-order products are final sale. Cancellations are free any time before shipment (custom orders excepted). Threshold and white-glove delivery upgrades are available — ask our team.

    Full shipping policy · Full return policy · Questions? Call (410) 324-6322 — when you call, we answer.

    Warranty

    In the unlikely event your product experiences a defect, our technical team will guide you through the manufacturer’s warranty process. Here is a general outline of what to expect.

    Due to the technical nature of our products, the manufacturer must perform troubleshooting to process a warranty claim. Your installer will need to troubleshoot the problem on-site while working in tandem with our technical team. If troubleshooting leads to what The Torch Guys deems as a defective part, we will submit a warranty claim to the manufacturer on your behalf. Before we submit the claim, we will ask you to review the terms and confirm your consent to proceed.

    Once the claim is submitted, the manufacturer will review it and either approve or deny it. If they have all the information and accept the claim, your warranty replacement part(s) will begin processing for shipment. If, for any reason, the claim is denied or we need more information, we will notify you as soon as possible.

    All warranties are processed as exchanges. You can expect to receive a prepaid return label for the defective part(s), which must be returned within 30 days of receiving the warranty replacement(s).

    Warranty claims can take anywhere from 1-4 weeks to process, depending on the season. Given the length of time claims can take, we recommend you fire up your unit in late summer/early fall to ensure your existing fireplace is in good working order for the winter season.